Electronic absorption from first principles to the bench: the physics behind each band, the equations you will actually use, and interactive models to test your intuition. Drag, click and change the numbers.
UV–Vis photons (≈190–800 nm, 1.5–6.5 eV) carry enough energy to promote valence electrons between molecular orbitals. Click anywhere on the spectrum or drag the slider to convert between units.
Compare: a C–C bond is ≈ 348 kJ mol⁻¹, a C=C π bond ≈ 265 kJ mol⁻¹. Light below ≈ 340 nm can therefore drive photochemistry, not only absorption.
Energy is linear in wavenumber, not in wavelength. Band widths, shifts and integrals should be computed in cm⁻¹ or eV. A 10 nm shift at 250 nm is 0.20 eV; the same shift at 600 nm is only 0.035 eV.
Each absorption band corresponds to promotion from an occupied to an unoccupied orbital. The type of transition fixes its typical wavelength, intensity and solvent response. Select a transition.
Absorbance is linear in concentration only for monochromatic light, dilute non-interacting absorbers, and an instrument without stray light. Move the sliders and watch the observed line bend away from the ideal one.
Each thin slab dx removes a fraction of the photons proportional to the number of absorbers it contains:
Absorbances are additive over independent absorbers: \(A(\lambda) = b\sum_i \varepsilon_i(\lambda)\,c_i\).
Chemical deviations (dimerisation, acid–base equilibria, H-/J-aggregation) and polychromatic light (bandwidth comparable to the band width) also give curvature. Keep A between about 0.1 and 1.0 for quantitative work.
The integrated intensity of a band measures the transition dipole moment. Selection rules decide whether it is large; vibrational structure and the solvent decide its shape.
Born–Oppenheimer factorisation (Ψ = ψelχvibS):
Any factor that vanishes makes the transition “forbidden”. Rate from Fermi’s golden rule: \(W_{i\to f} = \tfrac{2\pi}{\hbar}|\langle f|\hat H'|i\rangle|^2\rho(E)\).
f is dimensionless; f ≈ 1 is a fully allowed one-electron transition. For a Gaussian band \(\int\varepsilon\,\mathrm d\tilde\nu = 1.0645\,\varepsilon_\text{max}\,\Delta\tilde\nu_{1/2}\).
Absorption strength sets the radiative rate. The Strickler–Berg relation links the absorption band to the natural fluorescence lifetime:
| Rule | Statement | If violated |
|---|---|---|
| Spin | ΔS = 0 (singlet ↔ singlet) | ε ≲ 1 |
| Laporte (parity) | g ↔ u only, in centrosymmetric systems | ε ≈ 1–100 |
| Symmetry | Γf ⊗ Γμ ⊗ Γi ⊃ A1 | ε ≈ 10–1000 |
| Overlap | donor and acceptor orbitals must overlap in space | weak CT |
Forbidden bands still appear through vibronic coupling (Herzberg–Teller), spin–orbit coupling (heavy atoms) and symmetry lowering by the environment.
The Franck–Condon progression depends on the Huang–Rhys factor S, set by the excited-state displacement. Solution spectra blur the progression through solvent inhomogeneity, so λmax is the vertical transition, not the 0–0 energy.
Defaults approximate β-carotene in hexane. Try εmax = 15, λmax = 279, FWHM = 40 (acetone n→π*): f drops by four orders of magnitude.
Delocalised π electrons in a polyene behave roughly like particles in a one-dimensional box. The free-electron model gets the trend right but overshoots for long chains. Kuhn’s correction adds a bond-alternation potential V₀ that keeps a finite gap.
| Increment | nm each | Count |
|---|
| Parent / increment | nm |
|---|---|
| Acyclic or 6-ring enone | 215 |
| 5-ring enone | 202 |
| α,β-unsaturated aldehyde | 210 |
| Acid / ester | 195 |
| Extending C=C | +30 |
| Homoannular diene component | +39 |
| Alkyl / ring residue at α, β, γ and higher | +10, +12, +18 |
| Exocyclic C=C | +5 |
| –OH at α / β | +35 / +30 |
| –NR₂ at β | +95 |
Solvent correction for enones (relative to ethanol): water −8, methanol 0, chloroform +1, hexane +11 nm. Rules are empirical; expect ±5 nm for rigid steroids and worse for twisted systems.
When exactly two species interconvert at constant total concentration, all spectra cross at wavelengths where their ε values are equal. A drifting crossing point signals a third species, decomposition, or a dilution error.
Near the absorption edge of a semiconductor, α follows a power law in (hν − Eg). The exponent depends on the transition type, and choosing the wrong one biases Eg. Try analysing a direct-gap material as if it were indirect.
For powders measured by diffuse reflectance, replace α with the Kubelka–Munk function \(F(R_\infty) = (1-R_\infty)^2/2R_\infty\). Fit only the linear region and report which exponent you used; see Makuła et al. (2018).
Select a component to see what it does and which specification matters when you choose settings or write the methods section.
Wavelength where a 1 cm cell of solvent reaches A ≈ 1 against air. Do not trust data below it.
| Solvent | Cutoff | 190 → 400 nm |
|---|
| Material | Usable from | Notes |
|---|---|---|
| Far-UV quartz (fused silica) | ≈ 190 nm | Standard for UV work; reusable |
| UV-grade plastic | ≈ 220–230 nm | Disposable; check the batch for DNA at 260 nm |
| Optical glass | ≈ 320–340 nm | Visible only |
| Polystyrene | ≈ 340 nm | Visible only; attacked by organics |
| PMMA | ≈ 280–300 nm | Near-UV; attacked by many solvents |
Particles and aggregates scatter light (Rayleigh ∝ λ⁻⁴), which the detector records as extinction. Filter or centrifuge, or fit and subtract a λ⁻ⁿ background. For turbid samples use an integrating sphere.
Dyes stack at µM–mM. H-aggregates blue-shift, J-aggregates red-shift and sharpen. Test by dilution: a true monomer gives identical ε at every concentration.
The probe beam can bleach or isomerise sensitive samples (azobenzenes, retinals). Repeat scans and compare; use fast scanning or a diode-array instrument.
A strongly fluorescent sample in a single-beam instrument with post-sample dispersion can appear less absorbing. Instruments that disperse before the sample avoid this.
Instrument model, spectral bandwidth, scan rate or integration time, path length, solvent grade, temperature, concentration range, and ε with uncertainty from a calibration series.
Report ε in M⁻¹ cm⁻¹ (= L mol⁻¹ cm⁻¹). In SI, m² mol⁻¹ is 10 times smaller in value: 1 M⁻¹cm⁻¹ = 0.1 m² mol⁻¹. Absorbance itself has no unit, so do not write “a.u.” for A.
Equations for the analyses that most often appear in PhD work. Each assumes Beer–Lambert behaviour for every species involved.
Measure at many more wavelengths than components. Singular value decomposition of a spectral series gives the number of independent absorbing species.
No ε needed. Stopped-flow extends this to milliseconds; global fitting uses all wavelengths at once.
Valid only for [G]₀ ≫ [H]₀. Nonlinear fitting of the full isotherm is preferred. A Job plot (ΔA against mole fraction of guest) peaks at x = n/(n+1) for HGₙ, but misleads when several complexes coexist.
A band’s maximum becomes a sharp minimum in the second derivative, which narrows peaks and suppresses sloping baselines. Signal-to-noise falls with each order, so smooth first (Savitzky–Golay).
The slope of the Stokes shift against solvent orientation polarisability gives the change in dipole moment on excitation.
Face-to-face stacking (H) gives a blue shift, head-to-tail (J) a red shift. Circular dichroism exciton couplets report the relative orientation of the chromophores.
For d² to d⁸ ions use Tanabe–Sugano diagrams to extract Δo and the Racah parameter B from two band positions.
TD-DFT gives vertical excitation energies and f. Broaden each line with a Gaussian (FWHM ≈ 0.3 eV) and sum:
σ in cm⁻¹ (σ = FWHM/(2√ln 2)). Expect errors of 0.2–0.4 eV that depend on the functional; charge-transfer states need range-separated hybrids and an implicit solvent model.
Score: 0 / 7