UV–Vis Spectroscopy Atlas
A working atlas for graduate researchers

UV–Vis Spectroscopy

Electronic absorption from first principles to the bench: the physics behind each band, the equations you will actually use, and interactive models to test your intuition. Drag, click and change the numbers.

01 · The energy scale

Where UV–Vis sits, and what each photon can do

UV–Vis photons (≈190–800 nm, 1.5–6.5 eV) carry enough energy to promote valence electrons between molecular orbitals. Click anywhere on the spectrum or drag the slider to convert between units.

Live · unit converter
254 nm
Photon energy
–
Wavenumber
–
Molar energy
–
Frequency
–
Region
–
Seen as
–

Compare: a C–C bond is ≈ 348 kJ mol⁻¹, a C=C π bond ≈ 265 kJ mol⁻¹. Light below ≈ 340 nm can therefore drive photochemistry, not only absorption.

Unit relations

\[ E = h\nu = \frac{hc}{\lambda} = hc\,\tilde{\nu} \]
\[ E\,[\mathrm{eV}] = \frac{1239.84}{\lambda\,[\mathrm{nm}]}, \qquad \tilde{\nu}\,[\mathrm{cm^{-1}}] = \frac{10^{7}}{\lambda\,[\mathrm{nm}]} \]
\[ 1\ \mathrm{eV} = 8065.54\ \mathrm{cm^{-1}} = 96.485\ \mathrm{kJ\,mol^{-1}} \]

Energy is linear in wavenumber, not in wavelength. Band widths, shifts and integrals should be computed in cm⁻¹ or eV. A 10 nm shift at 250 nm is 0.20 eV; the same shift at 600 nm is only 0.035 eV.

02 · Electronic transitions

Which electron moves, and where to

Each absorption band corresponds to promotion from an occupied to an unoccupied orbital. The type of transition fixes its typical wavelength, intensity and solvent response. Select a transition.

Transition

π → π*

Typical λmax
Typical εmax / M⁻¹cm⁻¹
Polar solvent
Example

Vocabulary of shifts

Bathochromic
shift to longer λ (red shift, lower energy)
Hypsochromic
shift to shorter λ (blue shift, higher energy)
Hyperchromic
increase in ε
Hypochromic
decrease in ε
Chromophore
group responsible for absorption (C=C, C=O, N=N, NO₂, arene)
Auxochrome
non-absorbing substituent with lone pairs (–OH, –NH₂, –OR, –Cl) that shifts a chromophore’s band, usually bathochromically
03 · Quantitation

The Beer–Lambert law and where it breaks

Absorbance is linear in concentration only for monochromatic light, dilute non-interacting absorbers, and an instrument without stray light. Move the sliders and watch the observed line bend away from the ideal one.

Derivation in three lines

Each thin slab dx removes a fraction of the photons proportional to the number of absorbers it contains:

\[ \frac{\mathrm{d}I}{\mathrm{d}x} = -\kappa\, c\, I \;\;\Longrightarrow\;\; \ln\frac{I_0}{I} = \kappa\, c\, b \]
\[ A \equiv \log_{10}\frac{I_0}{I} = -\log_{10} T = \varepsilon\, b\, c, \qquad \varepsilon = \frac{\kappa}{\ln 10} \]
\[ \sigma\,[\mathrm{cm^2}] = \frac{\ln(10)\,\varepsilon}{N_\mathrm{A}} = 3.82\times10^{-21}\,\varepsilon\,[\mathrm{M^{-1}cm^{-1}}] \]

Absorbances are additive over independent absorbers: \(A(\lambda) = b\sum_i \varepsilon_i(\lambda)\,c_i\).

Deviations you will meet

\[ A_\text{obs} = -\log_{10}\!\left(\frac{10^{-A} + s}{1+s}\right) \quad \text{(stray-light fraction } s\text{)} \]
\[ \frac{\Delta c}{c} = \frac{0.434\,\Delta T}{T\,\log_{10} T}\quad\Rightarrow\quad \text{minimum at } T = e^{-1},\; A = 0.434 \]

Chemical deviations (dimerisation, acid–base equilibria, H-/J-aggregation) and polychromatic light (bandwidth comparable to the band width) also give curvature. Keep A between about 0.1 and 1.0 for quantitative work.

Live · virtual cuvette
15 000 M⁻¹cm⁻¹
40 µM
0.10 %
0.50 %T
True A
–
Observed A
–
%T
–
Error in c
–

Calibration: A vs c

ideal εbcobserved with stray light

Relative concentration error vs absorbance

constant ΔT noiseyour sample
04 · Quantum mechanics of a band

Why some bands are strong, some are weak, and all are broad

The integrated intensity of a band measures the transition dipole moment. Selection rules decide whether it is large; vibrational structure and the solvent decide its shape.

Transition dipole moment

\[ \boldsymbol{\mu}_{fi} = \langle \Psi_f \,|\, \hat{\boldsymbol{\mu}} \,|\, \Psi_i \rangle, \qquad \hat{\boldsymbol{\mu}} = -e\sum_k \mathbf{r}_k \]

Born–Oppenheimer factorisation (Ψ = ψelχvibS):

\[ \boldsymbol{\mu}_{fi} \approx \underbrace{\langle \psi_f|\hat{\boldsymbol\mu}|\psi_i\rangle}_{\text{orbital / symmetry}} \; \underbrace{\langle \chi_{v'}|\chi_{v}\rangle}_{\text{Franck–Condon}} \; \underbrace{\langle S_f|S_i\rangle}_{\text{spin}} \]

Any factor that vanishes makes the transition “forbidden”. Rate from Fermi’s golden rule: \(W_{i\to f} = \tfrac{2\pi}{\hbar}|\langle f|\hat H'|i\rangle|^2\rho(E)\).

Oscillator strength

\[ f = \frac{8\pi^2 m_e \nu}{3 h e^2}\,|\boldsymbol{\mu}_{fi}|^2 \quad(\text{Gaussian units}) \]
\[ f_\text{exp} = 4.32\times10^{-9}\int \varepsilon(\tilde\nu)\,\mathrm{d}\tilde\nu \]

f is dimensionless; f ≈ 1 is a fully allowed one-electron transition. For a Gaussian band \(\int\varepsilon\,\mathrm d\tilde\nu = 1.0645\,\varepsilon_\text{max}\,\Delta\tilde\nu_{1/2}\).

\[ |\boldsymbol{\mu}_{fi}|^2\,[\mathrm{D^2}] = 9.186\times10^{-3}\int \frac{\varepsilon(\tilde\nu)}{\tilde\nu}\,\mathrm{d}\tilde\nu \]

Einstein coefficients

\[ A_{21} = \frac{8\pi h \nu^3}{c^3}\,B_{21}, \qquad g_1 B_{12} = g_2 B_{21} \]

Absorption strength sets the radiative rate. The Strickler–Berg relation links the absorption band to the natural fluorescence lifetime:

\[ k_r = \frac{1}{\tau_0} \approx 2.88\times10^{-9}\, n^2\, \tilde\nu_\text{max}^2 \int\varepsilon\,\mathrm{d}\tilde\nu \]

Selection rules and the intensities they predict

RuleStatementIf violated
SpinΔS = 0 (singlet ↔ singlet)ε ≲ 1
Laporte (parity)g ↔ u only, in centrosymmetric systemsε ≈ 1–100
SymmetryΓf ⊗ Γμ ⊗ Γi ⊃ A1ε ≈ 10–1000
Overlapdonor and acceptor orbitals must overlap in spaceweak CT

Forbidden bands still appear through vibronic coupling (Herzberg–Teller), spin–orbit coupling (heavy atoms) and symmetry lowering by the environment.

Band shape

\[ \varepsilon(\tilde\nu) = \varepsilon_\text{max}\exp\!\left[-4\ln 2\,\frac{(\tilde\nu-\tilde\nu_0)^2}{\Delta\tilde\nu_{1/2}^{\,2}}\right] \]
\[ I_{0\to v'} \propto |\langle\chi_{v'}|\chi_0\rangle|^2 = e^{-S}\frac{S^{v'}}{v'!} \]

The Franck–Condon progression depends on the Huang–Rhys factor S, set by the excited-state displacement. Solution spectra blur the progression through solvent inhomogeneity, so λmax is the vertical transition, not the 0–0 energy.

Live · from spectrum to transition dipole
FWHM
–
∫ε dν̃
–
Oscillator strength f
–
|μfi|
–
τ₀ (n = 1.36)
–

Defaults approximate β-carotene in hexane. Try εmax = 15, λmax = 279, FWHM = 40 (acetone n→π*): f drops by four orders of magnitude.

05 · Structure → colour

Conjugation lowers the HOMO–LUMO gap

Delocalised π electrons in a polyene behave roughly like particles in a one-dimensional box. The free-electron model gets the trend right but overshoots for long chains. Kuhn’s correction adds a bond-alternation potential V₀ that keeps a finite gap.

Live · polyene in a box
3
2.5 eV
π electrons
–
Box length L
–
Free-electron
–
With V₀
–
Experiment (hexane)
–
\[ E_n = \frac{n^2 h^2}{8 m_e L^2}, \qquad n_\text{HOMO} = N,\; n_\text{LUMO} = N+1 \]
\[ \Delta E = \frac{h^2}{8 m_e L^2}(2N+1) + V_0\!\left(1-\frac{1}{2N}\right), \qquad L = (2N+1)\,d_\text{CC} \]
free electron (V₀ = 0)with V₀experiment
Live · Woodward–Fieser, conjugated dienes
Incrementnm eachCount
Preset: cholesta-3,5-diene (obs. 235 nm) – nm

Enones (α,β-unsaturated carbonyls)

Parent / incrementnm
Acyclic or 6-ring enone215
5-ring enone202
α,β-unsaturated aldehyde210
Acid / ester195
Extending C=C+30
Homoannular diene component+39
Alkyl / ring residue at α, β, γ and higher+10, +12, +18
Exocyclic C=C+5
–OH at α / β+35 / +30
–NR₂ at β+95

Solvent correction for enones (relative to ethanol): water −8, methanol 0, chloroform +1, hexane +11 nm. Rules are empirical; expect ±5 nm for rigid steroids and worse for twisted systems.

06 · Equilibria

Isosbestic points and spectrophotometric pKa

When exactly two species interconvert at constant total concentration, all spectra cross at wavelengths where their ε values are equal. A drifting crossing point signals a third species, decomposition, or a dilution error.

Live · acid–base titration of a dye (50 µM, 1 cm)
7.0
7.2
0 %
HAA⁻current pHpH 2…12
\[ A(\lambda) = b\,c_\text{T}\left[\alpha_\text{HA}\,\varepsilon_\text{HA}(\lambda) + \alpha_{\text{A}^-}\varepsilon_{\text{A}^-}(\lambda)\right], \quad \alpha_{\text{A}^-} = \frac{1}{1+10^{\,\mathrm{p}K_a-\mathrm{pH}}} \]
\[ \mathrm{p}K_a = \mathrm{pH} + \log_{10}\frac{A_{\text{A}^-} - A}{A - A_\text{HA}} \]
Isosbestic λ
–
A420
–
pKa from eq.
–
07 · Solids and nanomaterials

Optical band gaps from Tauc plots

Near the absorption edge of a semiconductor, α follows a power law in (hν − Eg). The exponent depends on the transition type, and choosing the wrong one biases Eg. Try analysing a direct-gap material as if it were indirect.

Live · Tauc analysis
3.20 eV
50 meV
Material’s real transition
Tauc exponent you plot
True Eg
–
Tauc estimate
–
Bias
–
\[ (\alpha h\nu)^{1/\gamma} = B\,(h\nu - E_g), \qquad \gamma = \tfrac12\ \text{(direct)},\; 2\ \text{(indirect)} \]
\[ \alpha = \frac{2.303\,A}{d}, \qquad \alpha_\text{tail} = \alpha_0\exp\!\left(\frac{h\nu - E_g}{E_U}\right) \]

For powders measured by diffuse reflectance, replace α with the Kubelka–Munk function \(F(R_\infty) = (1-R_\infty)^2/2R_\infty\). Fit only the linear region and report which exponent you used; see Makuła et al. (2018).

08 · Hardware

Inside a double-beam spectrophotometer

Select a component to see what it does and which specification matters when you choose settings or write the methods section.

Component

09 · Bench practice

Solvents, cells and the mistakes reviewers spot

Solvent UV cutoff

Wavelength where a 1 cm cell of solvent reaches A ≈ 1 against air. Do not trust data below it.

SolventCutoff190 → 400 nm

Cuvette materials

MaterialUsable fromNotes
Far-UV quartz (fused silica)≈ 190 nmStandard for UV work; reusable
UV-grade plastic≈ 220–230 nmDisposable; check the batch for DNA at 260 nm
Optical glass≈ 320–340 nmVisible only
Polystyrene≈ 340 nmVisible only; attacked by organics
PMMA≈ 280–300 nmNear-UV; attacked by many solvents

Settings checklist

  • Spectral bandwidth ≤ ⅒ of the natural band FWHM (≈ 1–2 nm for solution work).
  • Baseline with the same solvent and matched cells; check the cell–cell offset.
  • Keep 0.1 < A < 1.0; dilute or change path length rather than trusting A > 2.
  • Record temperature; ε and equilibria are temperature-dependent.
  • Check linearity with at least five standards before reporting ε.
  • Note the D₂/tungsten lamp changeover (≈ 320–350 nm); small steps there are instrumental.
Scattering

A baseline that rises toward the UV

Particles and aggregates scatter light (Rayleigh ∝ λ⁻⁴), which the detector records as extinction. Filter or centrifuge, or fit and subtract a λ⁻ⁿ background. For turbid samples use an integrating sphere.

Aggregation

ε that depends on concentration

Dyes stack at µM–mM. H-aggregates blue-shift, J-aggregates red-shift and sharpen. Test by dilution: a true monomer gives identical ε at every concentration.

Photochemistry

The spectrum changes while you measure

The probe beam can bleach or isomerise sensitive samples (azobenzenes, retinals). Repeat scans and compare; use fast scanning or a diode-array instrument.

Fluorescence

Emission reaching the detector

A strongly fluorescent sample in a single-beam instrument with post-sample dispersion can appear less absorbing. Instruments that disperse before the sample avoid this.

Reporting

What belongs in the methods section

Instrument model, spectral bandwidth, scan rate or integration time, path length, solvent grade, temperature, concentration range, and ε with uncertainty from a calibration series.

Units

ε is not dimensionless

Report ε in M⁻¹ cm⁻¹ (= L mol⁻¹ cm⁻¹). In SI, m² mol⁻¹ is 10 times smaller in value: 1 M⁻¹cm⁻¹ = 0.1 m² mol⁻¹. Absorbance itself has no unit, so do not write “a.u.” for A.

10 · Beyond single spectra

Advanced quantitative methods

Equations for the analyses that most often appear in PhD work. Each assumes Beer–Lambert behaviour for every species involved.

Multicomponent

Unmixing overlapping spectra

\[ \mathbf{A} = b\,\mathbf{E}\,\mathbf{c}\;\Rightarrow\; \hat{\mathbf{c}} = \tfrac1b(\mathbf{E}^{\mathsf T}\mathbf{E})^{-1}\mathbf{E}^{\mathsf T}\mathbf{A} \]

Measure at many more wavelengths than components. Singular value decomposition of a spectral series gives the number of independent absorbing species.

Kinetics

First-order decay followed by absorbance

\[ \ln\frac{A_t - A_\infty}{A_0 - A_\infty} = -k_\text{obs}\,t \]

No ε needed. Stopped-flow extends this to milliseconds; global fitting uses all wavelengths at once.

Binding

Benesi–Hildebrand (1:1 host–guest)

\[ \frac{1}{\Delta A} = \frac{1}{b\,\Delta\varepsilon\,[\mathrm H]_0\,K_a}\frac{1}{[\mathrm G]_0} + \frac{1}{b\,\Delta\varepsilon\,[\mathrm H]_0} \]

Valid only for [G]₀ ≫ [H]₀. Nonlinear fitting of the full isotherm is preferred. A Job plot (ΔA against mole fraction of guest) peaks at x = n/(n+1) for HGₙ, but misleads when several complexes coexist.

Derivative spectra

Resolving shoulders

\[ \frac{\mathrm d^2A}{\mathrm d\lambda^2}\Big|_{\lambda_0} = -\frac{8\ln2\,A_\text{max}}{w^2}\ \ \text{(Gaussian)} \]

A band’s maximum becomes a sharp minimum in the second derivative, which narrows peaks and suppresses sloping baselines. Signal-to-noise falls with each order, so smooth first (Savitzky–Golay).

Solvatochromism

Lippert–Mataga analysis

\[ \tilde\nu_\text{abs}-\tilde\nu_\text{em} = \frac{2\Delta f}{hc\,a^3}(\mu_e-\mu_g)^2 + \text{const} \]
\[ \Delta f = \frac{\varepsilon_r-1}{2\varepsilon_r+1}-\frac{n^2-1}{2n^2+1} \]

The slope of the Stokes shift against solvent orientation polarisability gives the change in dipole moment on excitation.

Excitons

Coupled chromophores (Kasha)

\[ \Delta E_\text{split} = 2|V|, \quad V = \frac{|\mu|^2\,\kappa}{4\pi\varepsilon_0 r^3} \]
\[ \kappa = \cos\theta_{12} - 3\cos\theta_1\cos\theta_2 \]

Face-to-face stacking (H) gives a blue shift, head-to-tail (J) a red shift. Circular dichroism exciton couplets report the relative orientation of the chromophores.

Ligand field

d–d bands of complexes

\[ \Delta_o = \frac{hc}{\lambda_\text{max}}\ \ (d^1),\qquad \Delta_t \approx \tfrac49\Delta_o \]

For d² to d⁸ ions use Tanabe–Sugano diagrams to extract Δo and the Racah parameter B from two band positions.

Computation

Comparing with TD-DFT

TD-DFT gives vertical excitation energies and f. Broaden each line with a Gaussian (FWHM ≈ 0.3 eV) and sum:

\[ \varepsilon(\tilde\nu) \approx 1.3062\times10^{8}\sum_i \frac{f_i}{\sigma}\exp\!\left[-\left(\frac{\tilde\nu-\tilde\nu_i}{\sigma}\right)^{2}\right] \]

σ in cm⁻¹ (σ = FWHM/(2√ln 2)). Expect errors of 0.2–0.4 eV that depend on the functional; charge-transfer states need range-separated hybrids and an implicit solvent model.

11 · Self-check

Seven questions a committee might ask

Score: 0 / 7

12 · Further reading

References

  1. D. C. Harris, Quantitative Chemical Analysis, 10th ed., W. H. Freeman, 2020, chs. 18–19.
  2. N. J. Turro, V. Ramamurthy, J. C. Scaiano, Modern Molecular Photochemistry of Organic Molecules, University Science Books, 2010.
  3. J. R. Lakowicz, Principles of Fluorescence Spectroscopy, 3rd ed., Springer, 2006 (ch. 6 for solvent effects and Lippert–Mataga).
  4. H.-H. Perkampus, UV-VIS Spectroscopy and Its Applications, Springer, 1992.
  5. D. L. Pavia, G. M. Lampman, G. S. Kriz, J. R. Vyvyan, Introduction to Spectroscopy, 5th ed., Cengage, 2015 (Woodward–Fieser rules).
  6. R. C. Hilborn, “Einstein coefficients, cross sections, f values, dipole moments, and all that”, Am. J. Phys. 50 (1982) 982.
  7. S. J. Strickler, R. A. Berg, “Relationship between absorption intensity and fluorescence lifetime of molecules”, J. Chem. Phys. 37 (1962) 814.
  8. J. Tauc, R. Grigorovici, A. Vancu, “Optical properties and electronic structure of amorphous germanium”, Phys. Status Solidi 15 (1966) 627.
  9. P. Makuła, M. Pacia, W. Macyk, “How to correctly determine the band gap energy of modified semiconductor photocatalysts based on UV–Vis spectra”, J. Phys. Chem. Lett. 9 (2018) 6814.
  10. M. Kasha, H. R. Rawls, M. A. El-Bayoumi, “The exciton model in molecular spectroscopy”, Pure Appl. Chem. 11 (1965) 371.
  11. H. Kuhn, “A quantum-mechanical theory of light absorption of organic dyes and similar compounds”, J. Chem. Phys. 17 (1949) 1198.